Heal Force EB03 350W Surgical Electrocautery (Diathermy) Machine
250,000.00৳ Original price was: 250,000.00৳ .210,000.00৳ Current price is: 210,000.00৳ .
- EB03 electrosurgical generator comes with an easy-to-use interface.
- It ensures smooth cutting through all types of tissue.
- The electrosurgical generator has automatic current monitoring and program memory functions.
- It offers a maximum output of 350 watts.
- It has 6 monopolar and 1 bipolar output.
- The electrosurgical unit features isolated output, all floating.
- Adaptor for laparoscopy and thoracoscopy application is optional.
เฆชเงเฆฐเงเฆกเฆพเฆเงเฆเฆฟ เฆเงเฆจเฆพเฆฐ เฆเฆเง เฆเฆฎเฆพเฆฆเงเฆฐ เฆธเฆพเฆฅเง เฆฏเงเฆเฆพเฆฏเงเฆ เฆเฆฐเง เฆชเงเฆฐเงเฆกเฆพเฆเงเฆเฆฟเฆฐ เฆฌเฆฐเงเฆคเฆฎเฆพเฆจ เฆฆเฆพเฆฎ เฆธเฆฎเงเฆชเฆฐเงเฆเง เฆเงเฆจเง เฆจเฆฟเฆฌเง
Weight | 10 kg |
---|
Heal Force EB03 350W Surgical Electrocautery Machine โ Diathermy
EB03 electrosurgical generator is a versatile electrosurgical unit for all-around surgical procedures through all types of tissue. It has integrated seven power output, tissue responding, and automatic solid or split return electrode recognition functions, with which surgeons can perform highly precise and safe operations.
Application:ย EB03 is applicable in various surgeries such as general surgery, dermatology, plastic surgery, endoscopy, vascular surgery, heart/thoracic surgery, minimally invasive surgery, neurosurgery, and ophthalmology.
Heal Force electrosurgical unit features:ย
1. Multiple functions and working modes:
7 working modes are available, including single pole switching, condensing, bipolar switching and condensing. It is applicable to general surgery, obstetrics and gynecology, ENT, urology, cardiothoracic surgery, oncology, plastic surgery, etc.
2. Double isolation output:
CF level of power isolation for medical electronic products to prevent electric shock accidents.
3. Automatic recognition of single and double plate
4. The loop plate automatic recognition and detection system automatically detects and evaluates the effective contact area between the patientโs plate and skin in real-time, and displays it on the operation panel. If the contact area is found to fall to a dangerous level, all outputs will be automatically cut off, and an audible and visual alarm will be generated.
5. Tissue response technology:
Automatically adjust the output power according to different human tissues during surgery, effectively preventing excessive fluctuations in cutting and coagulation effects.
6. Dual CPU control:
The main control CPU and the monitoring CPU monitor the system output at the same time. Once the output exceeds the safety range, the monitoring CPU will cut off all outputs of the electric knife to ensure safety.
7. Fault code display:
Once the system has a fault, the control panel will automatically display the fault code, through which the fault causes can be easily queried.
Buy Best Price Patient Monitor from Medistore
Heal Force Electrosurgical Unit 350W
Product name
|
Heal Force Electrosurgical Unit 350W
|
|||
Power feature
|
Rate frequency
|
512 kHz (110/240vAC, 60/50Hz)
|
||
Isolated output
|
YES
|
|||
Quantitative display of contact area
|
YES, for the โSplitโ type of neutral electrode
|
|||
Contact area indicator lamp
|
10 lamps (one for 10% contact), alarm beep and flicker if contact < 20%
|
|||
Split/solid neutral electrode definition
|
YES, the โSplitโ or โSolidโ indicator lamp lights up
|
|||
Adjustable alarm volume
|
YES
|
|||
Operational duty cycle
|
10 seconds ON, 30 seconds OFF
|
|||
Cooling method
|
Convection
|
|||
Accessory & supply connection
|
Finger-switch pencil
|
1
|
||
Finger-switch pencil
|
2
|
|||
Patient return electrode
|
1
|
|||
Foot-switch
|
1
|
|||
AC power supply
|
1
|
|||
Equipotential bonding
|
1
|
|||
Surgical smoke evacuator
|
1 (but surgical smoke evacuator is optional)
|
|||
Regulation
|
Type according to EN 60601-1
|
CF
|
||
Protection class to EN 60601-1
|
class I
|
|||
Protection class to EN 60601-1
|
IIb
|
|||
Physical
|
Dimension (WxDxH)
|
330 x 450 x 150 mm
|
||
Weight
|
7.0 KG
|
Monopolar
|
||||
Cutting mode
|
Max. power output (watts)
|
Load (ohms)
|
Open circuit Vp-p
|
Crest factor
|
Pure Cut
|
350w (grey) / 150w (white)
|
500 ฮฉ
|
1,800 / 1,200v
|
1.5
|
Blend1
|
300w (grey) / 120w (white)
|
500 ฮฉ
|
2,700 / 2,000v
|
1.9
|
Blend2
|
200w (grey) / 80w (white)
|
500 ฮฉ
|
2,400 / 1,700v
|
2.3
|
Blend3
|
150w (grey) / 60w (white)
|
500 ฮฉ
|
2,900 / 3,000v
|
3.1
|
Coagulation mode
|
||||
Point
|
100w (grey) / 70w (white)
|
500 ฮฉ
|
4,600 / 3,900v
|
4.5
|
Soft
|
100w (grey) / 70w (white)
|
500 ฮฉ
|
3,600 / 3,300v
|
|
Bipolar
|
||||
Cutting mode
|
โ
|
โ
|
โ
|
โ
|
Standard
|
50w (grey) / 50w (white)
|
100 ฮฉ
|
600V
|
1.5
|